Alecto SMART-HEAT10
| Model | SMART-HEAT10 |
| Vendor | Alecto |
| Description | Radiator valve with thermostat |
| Exposes | lock (state), switch (state), battery, climate (current_heating_setpoint, local_temperature, system_mode), linkquality |
| Picture | ![]() |
Exposes
Lock
The current state of this lock is in the published state under the child_lock property (value is LOCK or UNLOCK). To control this lock publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"child_lock": "LOCK"} or {"child_lock": "UNLOCK"}. It's not possible to read (/get) this value.
Switch
The current state of this switch is in the published state under the window_detection property (value is ON or OFF). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"window_detection": "ON"}, {"window_detection": "OFF"} or {"window_detection": "TOGGLE"}. It's not possible to read (/get) this value.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported.. Value can be found in the published state on the battery property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.
Climate
This climate device supports the following features: current_heating_setpoint, local_temperature, system_mode.
current_heating_setpoint: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/setwith payload{"current_heating_setpoint": VALUE}whereVALUEis the °C between5and30. Reading (/get) this attribute is not possible.local_temperature: Current temperature measured on the device (in °C). Reading (/get) this attribute is not possible.system_mode: Mode of this device. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/setwith payload{"system_mode": VALUE}whereVALUEis one of:off,auto,heat. Reading (/get) this attribute is not possible.
Linkquality (numeric)