Options
thermostat_unit: Controls the temperature unit of the thermostat (default celsius). The value must be one ofcelsius,fahrenheit
Exposes
Climate (heat endpoint)
This climate device supports the following features: occupied_heating_setpoint, local_temperature, system_mode, running_state.
occupied_heating_setpoint: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/setwith payload{"occupied_heating_setpoint_heat": VALUE}whereVALUEis the °C between5and32. To read send a message tozigbee2mqtt/FRIENDLY_NAME/getwith payload{"occupied_heating_setpoint_heat": ""}.local_temperature: Current temperature measured on the device (in °C). To read send a message tozigbee2mqtt/FRIENDLY_NAME/getwith payload{"local_temperature_heat": ""}.system_mode: Mode of this device. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/setwith payload{"system_mode_heat": VALUE}whereVALUEis one of:off,auto,heat. To read send a message tozigbee2mqtt/FRIENDLY_NAME/getwith payload{"system_mode_heat": ""}.running_state: The current running state. Possible values are:idle,heat. To read send a message tozigbee2mqtt/FRIENDLY_NAME/getwith payload{"running_state_heat": ""}.
Temperature_setpoint_hold (binary, heat endpoint)
Prevent changes. false = run normally. true = prevent from making changes. Must be set to false when system_mode = off or true for heat. Value can be found in the published state on the temperature_setpoint_hold_heat property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"temperature_setpoint_hold_heat": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"temperature_setpoint_hold_heat": NEW_VALUE}. If value equals true temperature_setpoint_hold is ON, if false OFF.
Temperature_setpoint_hold_duration (numeric, heat endpoint)
Period in minutes for which the setpoint hold will be active. 65535 = attribute not used. 0 to 360 to match the remote display. Value can be found in the published state on the temperature_setpoint_hold_duration_heat property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"temperature_setpoint_hold_duration_heat": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"temperature_setpoint_hold_duration_heat": NEW_VALUE}. The minimal value is 0 and the maximum value is 65535.
Climate (water endpoint)
This climate device supports the following features: occupied_heating_setpoint, local_temperature, system_mode, running_state.
occupied_heating_setpoint: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/setwith payload{"occupied_heating_setpoint_water": VALUE}whereVALUEis the °C between22and22. To read send a message tozigbee2mqtt/FRIENDLY_NAME/getwith payload{"occupied_heating_setpoint_water": ""}.local_temperature: Current temperature measured on the device (in °C). To read send a message tozigbee2mqtt/FRIENDLY_NAME/getwith payload{"local_temperature_water": ""}.system_mode: Mode of this device. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/setwith payload{"system_mode_water": VALUE}whereVALUEis one of:off,auto,heat,emergency_heating. To read send a message tozigbee2mqtt/FRIENDLY_NAME/getwith payload{"system_mode_water": ""}.running_state: The current running state. Possible values are:idle,heat. To read send a message tozigbee2mqtt/FRIENDLY_NAME/getwith payload{"running_state_water": ""}.
Temperature_setpoint_hold (binary, water endpoint)
Prevent changes. false = run normally. true = prevent from making changes. Must be set to false when system_mode = off or true for heat. Value can be found in the published state on the temperature_setpoint_hold_water property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"temperature_setpoint_hold_water": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"temperature_setpoint_hold_water": NEW_VALUE}. If value equals true temperature_setpoint_hold is ON, if false OFF.
Temperature_setpoint_hold_duration (numeric, water endpoint)
Period in minutes for which the setpoint hold will be active. 65535 = attribute not used. 0 to 360 to match the remote display. Value can be found in the published state on the temperature_setpoint_hold_duration_water property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"temperature_setpoint_hold_duration_water": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"temperature_setpoint_hold_duration_water": NEW_VALUE}. The minimal value is 0 and the maximum value is 65535.