TuYa JM-TRH-ZGB-V1
Model | JM-TRH-ZGB-V1 |
Vendor | TuYa |
Description | Temperature & humidity sensor with clock |
Exposes | temperature, humidity, battery, temperature_report_interval, temperature_unit_convert, temperature_alarm, max_temperature, min_temperature, humidity_alarm, max_humidity, min_humidity, linkquality |
Picture |
Options
temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.
Exposes
Temperature (numeric)
Measured temperature value. Value can be found in the published state on the temperature
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is °C
.
Humidity (numeric)
Measured relative humidity. Value can be found in the published state on the humidity
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is %
.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported.. Value can be found in the published state on the battery
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Temperature_report_interval (numeric)
Temperature Report interval. Value can be found in the published state on the temperature_report_interval
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_report_interval": NEW_VALUE}
. The minimal value is 5
and the maximum value is 60
. The unit of this value is min
.
Temperature_unit_convert (enum)
Current display unit. Value can be found in the published state on the temperature_unit_convert
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_unit_convert": NEW_VALUE}
. The possible values are: celsius
, fahrenheit
.
Temperature_alarm (enum)
Temperature alarm status. Value can be found in the published state on the temperature_alarm
property. It's not possible to read (/get
) or write (/set
) this value. The possible values are: canceled
, lower_alarm
, upper_alarm
.
Max_temperature (numeric)
Alarm temperature max. Value can be found in the published state on the max_temperature
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"max_temperature": NEW_VALUE}
. The minimal value is -20
and the maximum value is 60
. The unit of this value is °C
.
Min_temperature (numeric)
Alarm temperature min. Value can be found in the published state on the min_temperature
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"min_temperature": NEW_VALUE}
. The minimal value is -20
and the maximum value is 60
. The unit of this value is °C
.
Humidity_alarm (enum)
Humidity alarm status. Value can be found in the published state on the humidity_alarm
property. It's not possible to read (/get
) or write (/set
) this value. The possible values are: canceled
, lower_alarm
, upper_alarm
.
Max_humidity (numeric)
Alarm humidity max. Value can be found in the published state on the max_humidity
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"max_humidity": NEW_VALUE}
. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Min_humidity (numeric)
Alarm humidity min. Value can be found in the published state on the min_humidity
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"min_humidity": NEW_VALUE}
. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.