HEIMAN HS2WD-E
| Model | HS2WD-E |
| Vendor | HEIMAN |
| Description | Smart siren |
| Exposes | battery, warning, linkquality |
| Picture | ![]() |
Notes
Triggering the alarm
The alarm can be trigged by publishing to zigbee2mqtt/FRIENDLY_NAME/set message {"warning": {"duration": 10, "mode": "emergency", "strobe": false}}.
Where:
duration: the number of seconds the alarm will be on (max is 1800 seconds)mode:stoporemergencystrobe:trueorfalsewill let the strobe flash once during the alarm
Exposes
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported.. Value can be found in the published state on the battery property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.
Warning (composite)
Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set with payload {"warning": {"mode": VALUE, "level": VALUE, "strobe_level": VALUE, "strobe": VALUE, "strobe_duty_cycle": VALUE, "duration": VALUE}}
mode(enum): Mode of the warning (sound effect) allowed values:stop,burglar,fire,emergency,police_panic,fire_panic,emergency_paniclevel(enum): Sound level allowed values:low,medium,high,very_highstrobe_level(enum): Intensity of the strobe allowed values:low,medium,high,very_highstrobe(binary): Turn on/off the strobe (light) during warning allowed values:trueorfalsestrobe_duty_cycle(numeric): Length of the flash cycle max value is 10duration(numeric): Duration in seconds of the alarm unit is s
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.