HEIMAN HS2AQ-EM
| Model | HS2AQ-EM |
| Vendor | HEIMAN |
| Description | Air quality monitor |
| Exposes | battery, temperature, humidity, pm25, hcho, voc, aqi, pm10, battery_state, linkquality |
| Picture | ![]() |
Options
temperature_precision: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of0and with a with a maximum value of3temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.humidity_precision: Number of digits after decimal point for humidity, takes into effect on next report of device. The value must be a number with a minimum value of0and with a with a maximum value of3humidity_calibration: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.
Exposes
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported.. Value can be found in the published state on the battery property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.
Temperature (numeric)
Measured temperature value. Value can be found in the published state on the temperature property. It's not possible to read (/get) or write (/set) this value. The unit of this value is °C.
Humidity (numeric)
Measured relative humidity. Value can be found in the published state on the humidity property. It's not possible to read (/get) or write (/set) this value. The unit of this value is %.
Pm25 (numeric)
Measured PM2.5 (particulate matter) concentration. Value can be found in the published state on the pm25 property. It's not possible to read (/get) or write (/set) this value. The unit of this value is µg/m³.
Hcho (numeric)
Measured Hcho value. Value can be found in the published state on the hcho property. It's not possible to read (/get) or write (/set) this value. The unit of this value is mg/m³.
Voc (numeric)
Measured VOC value. Value can be found in the published state on the voc property. It's not possible to read (/get) or write (/set) this value. The unit of this value is µg/m³.
Aqi (numeric)
Air quality index. Value can be found in the published state on the aqi property. It's not possible to read (/get) or write (/set) this value.
Pm10 (numeric)
Measured PM10 (particulate matter) concentration. Value can be found in the published state on the pm10 property. It's not possible to read (/get) or write (/set) this value. The unit of this value is µg/m³.
Battery_state (enum)
Value can be found in the published state on the battery_state property. It's not possible to read (/get) or write (/set) this value. The possible values are: not_charging, charging, charged.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.