Lidl HG06338
Model | HG06338 |
Vendor | Lidl |
Description | Silvercrest 3 gang switch, with 4 USB (EU, FR, CZ, BS) |
Exposes | switch (state), power_on_behavior, linkquality |
Picture |
Notes
Pairing
Factory reset the 3 gang switch by holding the power button for 5 seconds. When you let go of the button an LED should blink. After resetting the 3 gang switch will automatically connect.
While pairing, keep the 3 gang switch close to the adapter.
Node-Red
How to use the connector strip with Node-Red: Use the "command node" of the node-red-contrib-zigbee-package. Drop-down-lists are helping you with the configuration.
Options
state_action
: State actions will also be published as 'action' when true (default false). The value must betrue
orfalse
Exposes
Switch (l1 endpoint)
The current state of this switch is in the published state under the state_l1
property (value is ON
or OFF
). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state_l1": "ON"}
, {"state_l1": "OFF"}
or {"state_l1": "TOGGLE"}
. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state_l1": ""}
.
Switch (l2 endpoint)
The current state of this switch is in the published state under the state_l2
property (value is ON
or OFF
). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state_l2": "ON"}
, {"state_l2": "OFF"}
or {"state_l2": "TOGGLE"}
. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state_l2": ""}
.
Switch (l3 endpoint)
The current state of this switch is in the published state under the state_l3
property (value is ON
or OFF
). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state_l3": "ON"}
, {"state_l3": "OFF"}
or {"state_l3": "TOGGLE"}
. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state_l3": ""}
.
Power_on_behavior (enum)
Controls the behavior when the device is powered on after power loss. Value can be found in the published state on the power_on_behavior
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"power_on_behavior": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"power_on_behavior": NEW_VALUE}
. The possible values are: off
, previous
, on
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.