Custom devices (DiY) EFEKTA_iAQ
Model | EFEKTA_iAQ |
Vendor | Custom devices (DiY) |
Description | CO2 Monitor with IPS TFT Display, outdoor temperature and humidity, date and time |
Exposes | co2, temperature, humidity, illuminance, auto_brightness, long_chart_period, set_altitude, local_time, temperature_offset, humidity_offset, forced_recalibration, factory_reset_co2, manual_forced_recalibration, linkquality |
Picture |
Options
temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.illuminance_calibration
: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number.illuminance_lux_calibration
: Calibrates the illuminance_lux value (percentual offset), takes into effect on next report of device. The value must be a number.
Exposes
Co2 (numeric)
The measured CO2 (carbon dioxide) value. Value can be found in the published state on the co2
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is ppm
.
Temperature (numeric)
Measured temperature value. Value can be found in the published state on the temperature
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is °C
.
Humidity (numeric)
Measured relative humidity. Value can be found in the published state on the humidity
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is %
.
Illuminance (numeric)
Raw measured illuminance. Value can be found in the published state on the illuminance
property. It's not possible to read (/get
) or write (/set
) this value.
Auto_brightness (binary)
Enable or Disable Auto Brightness of the Display. Value can be found in the published state on the auto_brightness
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"auto_brightness": NEW_VALUE}
. If value equals ON
auto_brightness is ON, if OFF
OFF.
Long_chart_period (binary)
The period of plotting the CO2 level(OFF - 1H | ON - 24H). Value can be found in the published state on the long_chart_period
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"long_chart_period": NEW_VALUE}
. If value equals ON
long_chart_period is ON, if OFF
OFF.
Set_altitude (numeric)
Setting the altitude above sea level (for high accuracy of the CO2 sensor). Value can be found in the published state on the set_altitude
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"set_altitude": NEW_VALUE}
. The minimal value is 0
and the maximum value is 3000
. The unit of this value is meters
.
Local_time (enum)
Set date and time. Value can be found in the published state on the local_time
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"local_time": NEW_VALUE}
. The possible values are: set
.
Temperature_offset (numeric)
Adjust temperature. Value can be found in the published state on the temperature_offset
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_offset": NEW_VALUE}
. The minimal value is -30
and the maximum value is 60
. The unit of this value is °C
.
Humidity_offset (numeric)
Adjust humidity. Value can be found in the published state on the humidity_offset
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"humidity_offset": NEW_VALUE}
. The minimal value is 0
and the maximum value is 99
. The unit of this value is %
.
Forced_recalibration (binary)
Start FRC (Perform Forced Recalibration of the CO2 Sensor). Value can be found in the published state on the forced_recalibration
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"forced_recalibration": NEW_VALUE}
. If value equals ON
forced_recalibration is ON, if OFF
OFF.
Factory_reset_co2 (binary)
Factory Reset CO2 sensor. Value can be found in the published state on the factory_reset_co2
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"factory_reset_co2": NEW_VALUE}
. If value equals ON
factory_reset_co2 is ON, if OFF
OFF.
Manual_forced_recalibration (numeric)
Start Manual FRC (Perform Forced Recalibration of the CO2 Sensor). Value can be found in the published state on the manual_forced_recalibration
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"manual_forced_recalibration": NEW_VALUE}
. The minimal value is 0
and the maximum value is 5000
. The unit of this value is ppm
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.