Custom devices (DiY) EFEKTA_eON213wz
| Model | EFEKTA_eON213wz |
| Vendor | Custom devices (DiY) |
| Description | Mini weather station, digital barometer, forecast, charts, temperature, humidity |
| Exposes | battery, temperature, humidity, pressure, linkquality |
| Picture | ![]() |
Notes
Build guide
Instructions on how to build this device can be found here
Options
temperature_precision: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of0and with a with a maximum value of3temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.humidity_precision: Number of digits after decimal point for humidity, takes into effect on next report of device. The value must be a number with a minimum value of0and with a with a maximum value of3humidity_calibration: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.pressure_precision: Number of digits after decimal point for pressure, takes into effect on next report of device. The value must be a number with a minimum value of0and with a with a maximum value of3pressure_calibration: Calibrates the pressure value (absolute offset), takes into effect on next report of device. The value must be a number.
Exposes
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported.. Value can be found in the published state on the battery property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.
Temperature (numeric)
Measured temperature value. Value can be found in the published state on the temperature property. It's not possible to read (/get) or write (/set) this value. The unit of this value is °C.
Humidity (numeric)
Measured relative humidity. Value can be found in the published state on the humidity property. It's not possible to read (/get) or write (/set) this value. The unit of this value is %.
Pressure (numeric)
The measured atmospheric pressure. Value can be found in the published state on the pressure property. It's not possible to read (/get) or write (/set) this value. The unit of this value is hPa.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.