TuYa D3-DPWK-TY
| Model | D3-DPWK-TY | 
| Vendor | TuYa | 
| Description | HVAC controller | 
| Exposes | climate (current_heating_setpoint, local_temperature, system_mode, running_state), linkquality | 
| Picture |  | 
Exposes
Climate
This climate device supports the following features: current_heating_setpoint, local_temperature, system_mode, running_state.
- current_heating_setpoint: Temperature setpoint. To control publish a message to topic- zigbee2mqtt/FRIENDLY_NAME/setwith payload- {"current_heating_setpoint": VALUE}where- VALUEis the °C between- 5and- 30. Reading (- /get) this attribute is not possible.
- local_temperature: Current temperature measured on the device (in °C). Reading (- /get) this attribute is not possible.
- system_mode: Mode of this device. To control publish a message to topic- zigbee2mqtt/FRIENDLY_NAME/setwith payload- {"system_mode": VALUE}where- VALUEis one of:- off,- auto,- heat. Reading (- /get) this attribute is not possible.
- running_state: The current running state. Possible values are:- idle,- heat,- cool. Reading (- /get) this attribute is not possible.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.