Schneider Electric CCTFR6700
| Model | CCTFR6700 |
| Vendor | Schneider Electric |
| Description | Heating thermostat |
| Exposes | power, energy, schneider_pilot_mode, climate (occupied_heating_setpoint, local_temperature, system_mode, pi_heating_demand), linkquality |
| Picture | ![]() |
Notes
Device info
This device is a thermostat to drive an electric heater. It supports two modes:
- Contactor mode, that switches the heater power supply on and off
- Pilot mode, for compatible heaters
Pairing and configuring
After pairing the device requires:
- the pilot mode to be configured (Contactor/Pilot)
- an external temperature measurement, either through a bind from a sensor, or report from the coordinator trhough automation. The temperature must be refreshed at least every 10mn
- the target thermostat set point
Local temperature
In order to provide external temperature measurement from the coordinator through automation, can be set by publishing a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"temperature_measured_value": VALUE} where VALUE is the temperature eg: 18.
Options
thermostat_unit: Controls the temperature unit of the thermostat (default celsius). The value must be one ofcelsius,fahrenheitpower_precision: Number of digits after decimal point for power, takes into effect on next report of device. The value must be a number with a minimum value of0and with a with a maximum value of3power_calibration: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number.energy_precision: Number of digits after decimal point for energy, takes into effect on next report of device. The value must be a number with a minimum value of0and with a with a maximum value of3energy_calibration: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number.
Exposes
Power (numeric)
Instantaneous measured power. Value can be found in the published state on the power property. It's not possible to read (/get) or write (/set) this value. The unit of this value is W.
Energy (numeric)
Sum of consumed energy. Value can be found in the published state on the energy property. It's not possible to read (/get) or write (/set) this value. The unit of this value is kWh.
Schneider_pilot_mode (enum)
Controls piloting mode. Value can be found in the published state on the schneider_pilot_mode property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"schneider_pilot_mode": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"schneider_pilot_mode": NEW_VALUE}. The possible values are: contactor, pilot.
Climate
This climate device supports the following features: occupied_heating_setpoint, local_temperature, system_mode, pi_heating_demand.
occupied_heating_setpoint: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/setwith payload{"occupied_heating_setpoint": VALUE}whereVALUEis the °C between4and30. To read send a message tozigbee2mqtt/FRIENDLY_NAME/getwith payload{"occupied_heating_setpoint": ""}.pi_heating_demand: Position of the valve (= demanded heat) where 0% is fully closed and 100% is fully open. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/setwith payload{"pi_heating_demand": VALUE}whereVALUEis the % between0and100. Reading (/get) this attribute is not possible.local_temperature: Current temperature measured on the device (in °C). To read send a message tozigbee2mqtt/FRIENDLY_NAME/getwith payload{"local_temperature": ""}.system_mode: Mode of this device. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/setwith payload{"system_mode": VALUE}whereVALUEis one of:off,auto,heat. To read send a message tozigbee2mqtt/FRIENDLY_NAME/getwith payload{"system_mode": ""}.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.