Schneider Electric CCTFR6400
| Model | CCTFR6400 |
| Vendor | Schneider Electric |
| Description | Temperature/Humidity measurement with thermostat interface |
| Exposes | keypad_lockout, humidity, battery, voltage, action, climate (occupied_heating_setpoint, local_temperature, pi_heating_demand), linkquality |
| Picture | ![]() |
Notes
Device info
This device is a
- thermostat UI for displaying/adjusting target set point.
- temperature sensor
- hygrometry sensor
It can display the heating status of associated climate by setting pi_heating_demand
It requires a Z-Stack controller (Firmware version > TBD). It is currently not working with zigate and conbee II (maybe supported in further firmware).
Options
temperature_precision: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of0and with a with a maximum value of3temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.humidity_precision: Number of digits after decimal point for humidity, takes into effect on next report of device. The value must be a number with a minimum value of0and with a with a maximum value of3humidity_calibration: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.
Exposes
Keypad_lockout (enum)
Enables/disables physical input on the device. Value can be found in the published state on the keypad_lockout property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"keypad_lockout": NEW_VALUE}. The possible values are: unlock, lock1, lock2.
Humidity (numeric)
Measured relative humidity. Value can be found in the published state on the humidity property. It's not possible to read (/get) or write (/set) this value. The unit of this value is %.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported.. Value can be found in the published state on the battery property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.
Voltage (numeric)
Voltage of the battery in millivolts. Value can be found in the published state on the voltage property. It's not possible to read (/get) or write (/set) this value. The unit of this value is mV.
Action (enum)
Triggered action (e.g. a button click). Value can be found in the published state on the action property. It's not possible to read (/get) or write (/set) this value. The possible values are: screen_sleep, screen_wake, button_press_plus_down, button_press_center_down, button_press_minus_down.
Climate
This climate device supports the following features: occupied_heating_setpoint, local_temperature, pi_heating_demand.
occupied_heating_setpoint: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/setwith payload{"occupied_heating_setpoint": VALUE}whereVALUEis the °C between4and30. Reading (/get) this attribute is not possible.pi_heating_demand: Position of the valve (= demanded heat) where 0% is fully closed and 100% is fully open. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/setwith payload{"pi_heating_demand": VALUE}whereVALUEis the % between0and100. Reading (/get) this attribute is not possible.local_temperature: Current temperature measured on the device (in °C). Reading (/get) this attribute is not possible.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.